Surface wires - Copper, PVC Insulated, PVC Sheathed Single core Cable (CU/PVC/PVC)

Products

1.5mm2 PVC insulated, PVC sheathed (NCYY 1.5 RS)

Nexans ref. 1601470S - Country ref. Ghana

  • Packaging: m
  • Approximate weight: 35.2 kg/km
  • Core diameter: 2.9 mm
  • Nominal conductor diameter: 1.5 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Nominal overall diameter: 4.5 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 22 A

 

2.5mm2 PVC insulated, PVC sheathed (NCYY 2.5 RS)

Nexans ref. 1601471S - Country ref. Ghana

  • Packaging: m
  • Approximate weight: 49 kg/km
  • Core diameter: 3.5 mm
  • Nominal conductor diameter: 1.9 mm
  • Nominal insulation thickness: 0.8 mm
  • Nominal outer sheath thickness: 0.8 mm
  • Nominal overall diameter: 5.1 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A

 

4.0mm2 PVC insulated, PVC sheathed (NCYY 4.0 RS)

Nexans ref. 1601475S - Country ref. Ghana

  • Packaging: m
  • Approximate weight: 84.1 kg/km
  • Core diameter: 4 mm
  • Nominal conductor diameter: 2.4 mm
  • Nominal insulation thickness: 0.8 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 6.8 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A

 

6.0mm2 PVC insulated, PVC sheathed (NCYY 6.0 RS)

Nexans ref. 1601350S - Country ref. Ghana

  • Packaging: m
  • Approximate weight: 111.9 kg/km
  • Core diameter: 5.4 mm
  • Nominal conductor diameter: 3.75 mm
  • Nominal insulation thickness: 0.8 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 8.2 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A

 

Description

Description

Standards

  • Product
    IEC 60227; IEC 60228 Class 2
  • Test
    IEC 60332-1-2

Scope

This specification covers PVC insulated, PVC sheathed, circular, single core cables, rated 0.45/0.75 KV according to IEC 60227 for  permanent wiring within buildings.

Design

Conductor
Plain, fine, annealed, electrolytic copper conductors, complying with the applicable requirements of IEC 60228.

Insulation
PVC 

Sheathing
PVC 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 2 acc. to IEC 60228
Conductor material
Annealed copper
Conductor shape
Circular non compacted
Core identification
Red,Black
Insulation
PVC
Number of conductors
1
Sheath colour
Grey

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Class 2 IEC 60228

Usage characteristics

Usage characteristics

Installation type
Indoor
Maximum operating temperature
70 °C

Resources

Resources

Selling & delivery Information

Roll of 100 yards (92m)

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close