Reduced earth Armored, XLPE Insulated, PVC sheathed Power Cable (NC2XRY 3 X 95 RS + 25 RS)
Reduced earth Armored, XLPE Insulated, PVC sheathed Power Cable (NC2XRY 3 X 95 RS + 25 RS)
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreDescription
Description
Standards
-
ProductIEC 60228 Class 2 ; IEC 60502-1
1. SCOPE
This specification covers XLPE insulated, circular, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2. CONSTRUCTION
2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded, conforming to the applicable requirements of IEC 60228.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Armour type
Galvanised round steel wires
Conductor flexibility
Class 2 acc. to IEC 60228
Conductor material
Annealed copper
Conductor shape
Circular compacted
Insulation
Cross-linked polyethylene
Material of bedding
Extruded compound
Material of filler / inner sheath
Filler if necessary
With smaller neutral conductor
Yes
Dimensional characteristics
Dimensional characteristics
Average insulation thickness
1.1 mm
Diameter over insulation
13.6 mm
External lay direction
Z
Insulation thickness of neutral conductor
0.90 mm
Maximum outer diameter
47.1 mm
Neutral Conductor Diameter
5.9 mm
Nominal Diameter under armour
35.6 mm
Nominal outer diameter
44.0 mm
Nominal outer sheath thickness
2.2 mm
Nominal weight
5136.1 g/m
Number of cores
4
Phase Conductor Diameter
11.4 mm
Electrical characteristics
Electrical characteristics
Max. DC resistance of the conductor at 20°C
0.193 Ohm/km
Permissible current rating buried/duct 20°C
347 A
Permissible current rating in open air
362 A
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Resistance of neutral conductor at 20ºC
0.727 Ohm/km
Usage characteristics
Usage characteristics
Max. conductor temperature in service
90 °C
Metric marking
METRIC MARKING