Multicore SWA Armored, XLPE insulated, LSZH sheathed
Multicore SWA Armored, XLPE insulated, LSZH sheathed
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreEXURU 13*1.5//UV
Nexans ref. EXURU 101292
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 764 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EXURU 14*1.5//UV
Nexans ref. EXURU 001292
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 782 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EXURU 2*1.5//UV
Nexans ref. EXURU 001285
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.5 mm
- Approximate weight: 280 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EXURU 2*10//UV
Nexans ref. EXURU 001269
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 716 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 80 A
- Permissible current rating when buried: 101 A
EXURU 2*16//UV
Nexans ref. EXURU 000625
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 911 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 107 A
- Permissible current rating when buried: 128 A
EXURU 2*2.5//UV
Nexans ref. EXURU 005225
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.0 mm
- Approximate weight: 330 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EXURU 2*4//UV
Nexans ref. EXURU 000745
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 395 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EXURU 2*6//UV
Nexans ref. EXURU 000746
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.5 mm
- Approximate weight: 472 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EXURU 20*4//UV
Nexans ref. EXURU 100739
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 1780 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EXURU 3*1.5//UV
Nexans ref. EXURU 001286
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.0 mm
- Approximate weight: 304 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EXURU 3*10//UV
Nexans ref. EXURU 001668
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.5 mm
- Approximate weight: 823 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXURU 3*16//UV
Nexans ref. EXURU 001664
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 1068 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXURU 3*185SM//UV
Nexans ref. EXURU 001666
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 50.0 mm
- Approximate weight: 7716 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EXURU 3*2.5//UV
Nexans ref. EXURU 001270
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Approximate weight: 364 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EXURU 3*2.5RE//N
Nexans ref. EXURU 000785
- Conductor shape: Circular solid (RE)
- Outer sheath: LSZH
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Approximate weight: 359 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EXURU 3*35//UV
Nexans ref. EXURU 001669
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 2002 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXURU 3*4//UV
Nexans ref. EXURU 000196
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 442 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EXURU 3*50//UV
Nexans ref. EXURU 003355
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2556 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXURU 3*6//UV
Nexans ref. EXURU 000621
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.0 mm
- Approximate weight: 537 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EXURU 4*10//UV
Nexans ref. EXURU 001273
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 964 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXURU 4*120SM//UV
Nexans ref. EXURU 004544
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 47.0 mm
- Approximate weight: 6823 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXURU 4*150SM//UV
Nexans ref. EXURU 001281
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 51.0 mm
- Approximate weight: 8115 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXURU 4*16//UV
Nexans ref. EXURU 001274
- Conductor shape: Circular
- Outer sheath: LSZH compound
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 23.0 mm
- Approximate weight: 1379 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXURU 4*185SM//UV
Nexans ref. EXURU 001282
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 56.0 mm
- Approximate weight: 9876 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EXURU 4*240SM//UV
Nexans ref. EXURU 001283
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 62.0 mm
- Approximate weight: 12367 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EXURU 4*25//UV
Nexans ref. EXURU 001275
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1928 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXURU 4*300SM//UV
Nexans ref. EXURU 001284
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 68.0 mm
- Approximate weight: 15155 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 595 A
- Permissible current rating when buried: 571 A
EXURU 4*35//UV
Nexans ref. EXURU 001276
- Conductor shape: Circular
- Outer sheath: LSZH compound
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2425 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXURU 4*4//UV
Nexans ref. EXURU 001271
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.0 mm
- Approximate weight: 520 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EXURU 4*50//UV
Nexans ref. EXURU 000015
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Approximate weight: 3099 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXURU 4*6//UV
Nexans ref. EXURU 001272
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 734 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EXURU 4*70SM//UV
Nexans ref. EXURU 001278
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 4052 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXURU 4*95SM//UV
Nexans ref. EXURU 001279
- Conductor shape: Sector-shaped stranded (SM)
- Outer sheath: LSZH
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 5194 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EXURU 5*1.5//UV
Nexans ref. EXURU 001291
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Approximate weight: 366 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EXURU 5*10//UV
Nexans ref. EXURU 000509
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 22.0 mm
- Approximate weight: 1128 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXURU 5*16//UV
Nexans ref. EXURU 005016
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 1620 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXURU 5*2.5//UV
Nexans ref. EXURU 000744
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.5 mm
- Approximate weight: 445 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EXURU 5*240//UV
Nexans ref. EXURU 005206
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 72.0 mm
- Approximate weight: 16212 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EXURU 5*4//UV
Nexans ref. EXURU 000504
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 696 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EXURU 5*6//UV
Nexans ref. EXURU 000506
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.5 mm
- Approximate weight: 849 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EXURU 6*1.5//UV
Nexans ref. EXURU 101291
- Conductor shape: Circular
- Outer sheath: LSZH
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 406 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EXURU 7*1.5//UV
Nexans ref. EXURU 001287
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 421 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EXURU 9*1.5//UV
Nexans ref. EXURU 001661
- Conductor shape: Circular
- Outer sheath: PVC
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.5 mm
- Approximate weight: 645 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-1-2
Scope
This specification covers XLPE insulated, circular or shaped, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.3 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.
2.4 Armour
Galvanized round wires completely covering the assembly of cores complying to the applicable requirements of IEC 60502-1.
2.5 Sheath
LSZH compound conforming to the applicable requirements of IEC 60502-1.
2.6 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania