- Markets
- Distributors
-
Products
- Products
-
Indoor Energy Cables
- Overview
- Building Wires - PVC Insulated Single Core Conduit Cable (CU/PVC)
- PVC Insulated, PVC Sheathed Multi Core Flexible Cable (CU/PVC/PVC FLEX)
- Copper, PVC Insulated, PVC Sheathed Multicore Cable (CU/PVC/PVC)
- Multicore Steel Wire Armored, XLPE insulated, PVC sheathed (CU/XLPE/SWA/PVC)
- Surface wires - Copper, PVC Insulated, PVC Sheathed Single core Cable (CU/PVC/PVC)
- Outdoor Energy Cables
- Building Wire
- Building Cables
- Bare Conductor
- Armored
- Aerial LV Cables
- Solar
- Flat Cable
- HFFR
- Control Cable
- Newsroom
- About Nexans
- Search
- Contact us
- Compare
- Sign in
Building Wires - PVC Insulated Single Core Conduit Cable (CU/PVC)
Building Wires - PVC Insulated Single Core Conduit Cable (CU/PVC)
Building wires, rated voltage 450/750V, CU/PVC flame retardant
Read moreNCY 1.5 RS
Nexans ref. NCY 1201509S - Country ref. Ghana
- Packaging: Coil (92m)
- Conductor flexibility: Class 2
- Conductor material: Bare copper stranded
- Approximate weight: 21 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal overall diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: - A
NCY 2.5 RS
Nexans ref. NCY 1201510S - Country ref. Ghana
- Packaging: Coil (92m)
- Conductor flexibility: Class 2
- Conductor material: Bare copper stranded
- Approximate weight: 33 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal overall diameter: 3.6 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 21 A
NCY 4.0 RS
Nexans ref. NCY 1201347S - Country ref. Ghana
- Packaging: Coil (92m)
- Conductor flexibility: Class 2
- Conductor material: Bare copper stranded
- Approximate weight: 49 kg/km
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal overall diameter: 4.2 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 28 A
NCY 6.0 RS
Nexans ref. NCY 1201306S - Country ref. Ghana
- Packaging: Coil (92m)
- Conductor flexibility: Stranded class 2
- Conductor material: Bare annealed copper stranded
- Approximate weight: 66 kg/km
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal overall diameter: 4.6 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 36 A
NCY 10.0 RS
Nexans ref. NCY 1201005S - Country ref. Ghana
- Packaging: Coil (92m)
- Conductor flexibility: Stranded class 2
- Conductor material: Bare copper stranded
- Approximate weight: 110 kg/km
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal overall diameter: 5.8 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 50 A
NCY 16.0 RS
Nexans ref. NCY 1201006S - Country ref. Ghana
- Packaging: Coil (92m)
- Conductor flexibility: Stranded class 2
- Conductor material: Bare annealed copper stranded
- Approximate weight: 165 kg/km
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal overall diameter: 6.7 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 68 A
NCY 25 RS
Nexans ref. NCY 1201007S - Country ref. Ghana
- Packaging: Coil (100m)
- Conductor flexibility: Class 2
- Conductor material: Bare copper stranded
- Approximate weight: 260.9 kg/km
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal overall diameter: 8.3 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
NCY 35 RS
Nexans ref. NCY 1201008S - Country ref. Ghana
- Packaging: Coil (100m)
- Conductor flexibility: Class 2
- Conductor material: Bare copper stranded
- Approximate weight: 351.02 kg/km
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal overall diameter: 9.3 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
Description
Description
Standards
-
ProductIEC 60227-3
-
TestIEC 60332-1-2
Application
The PVC insulated single core conduit cable are conductors without external sheath, but are PVC insulated. Ther are use for internal wiring in dry locations, concealed in conduits (residential or commercial buildings).
Design
Conductor
Plain, annealed, electrolytic copper conductors stranded, complying with the applicable requirements of IEC 60228.
Solid class 1 cable can aslso be produced based on customer request.
Insulation
PVC based thermoplastic material (Flame retardant)
Marking
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
A cable comes in a Roll of 100 yards (92m).
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania