Building Cables - Flexible cables

Products

NCY 1.5 RF

Nexans ref. NCY 1.5 RF

  • Packaging: Coil (100m)
  • Approximate weight: 20 kg/m
  • Diameter over insulation: 2.9 mm
  • Nominal conductor diameter: 1.3 mm
  • Nominal insulation thickness: 0.7 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Perm current rating in air 30°C: 16 A
  • Minimum Bend Radius - Installed: 18 mm

 

NCY 10.0 RF

Nexans ref. NCY 10.0 RF

  • Packaging: Coil (100m)
  • Approximate weight: 118 kg/m
  • Diameter over insulation: 5.9 mm
  • Nominal conductor diameter: 3.9 mm
  • Nominal insulation thickness: 1.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Perm current rating in air 30°C: 78 A
  • Minimum Bend Radius - Installed: 35 mm

 

NCY 120.0 RF

Nexans ref. NCY 120.0 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 1220 kg/m
  • Diameter over insulation: 17.8 mm
  • Nominal conductor diameter: 14.6 mm
  • Nominal insulation thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
  • Perm current rating in air 30°C: 365 A
  • Minimum Bend Radius - Installed: 107 mm

 

NCY 150.0 RF

Nexans ref. NCY 150 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 1480 kg/m
  • Diameter over insulation: 20.0 mm
  • Nominal conductor diameter: 16.4 mm
  • Nominal insulation thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • Perm current rating in air 30°C: 415 A
  • Minimum Bend Radius - Installed: 120 mm

 

NCY 16.0 RF

Nexans ref. NCY 16.0 RF

  • Packaging: Coil (100m)
  • Approximate weight: 176 kg/m
  • Diameter over insulation: 7.4 mm
  • Nominal conductor diameter: 5 mm
  • Nominal insulation thickness: 1.2 mm
  • Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
  • Perm current rating in air 30°C: 104 A
  • Minimum Bend Radius - Installed: 44 mm

 

NCY 185.0 RF

Nexans ref. NCY 185.0 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 1850 kg/m
  • Diameter over insulation: 22.0 mm
  • Nominal conductor diameter: 18 mm
  • Nominal insulation thickness: 2.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
  • Perm current rating in air 30°C: 475 A
  • Minimum Bend Radius - Installed: 132 mm

 

NCY 2.5 RF

Nexans ref. NCY 2.5 RF

  • Packaging: Coil (100m)
  • Approximate weight: 32 kg/m
  • Diameter over insulation: 3.4 mm
  • Nominal conductor diameter: 2 mm
  • Nominal insulation thickness: 0.7 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Perm current rating in air 30°C: 21 A
  • Minimum Bend Radius - Installed: 20 mm

 

NCY 240.0 RF

Nexans ref. NCY 240.0 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 2420 kg/m
  • Diameter over insulation: 25.4 mm
  • Nominal conductor diameter: 21 mm
  • Nominal insulation thickness: 2.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.0801 Ohm/km
  • Perm current rating in air 30°C: 560 A
  • Minimum Bend Radius - Installed: 152 mm

 

NCY 25.0 RF

Nexans ref. NCY 25.0 RF

  • Packaging: Coil (100m)
  • Approximate weight: 275 kg/m
  • Diameter over insulation: 8.6 mm
  • Nominal conductor diameter: 6.2 mm
  • Nominal insulation thickness: 1.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
  • Perm current rating in air 30°C: 137 A
  • Minimum Bend Radius - Installed: 52 mm

 

NCY 35.0 RF

Nexans ref. NCY 35.0 RF

  • Packaging: Coil (100m)
  • Approximate weight: 371 kg/m
  • Diameter over insulation: 10.2 mm
  • Nominal conductor diameter: 7.4 mm
  • Nominal insulation thickness: 1.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
  • Perm current rating in air 30°C: 168 A
  • Minimum Bend Radius - Installed: 61 mm

 

NCY 4.0 RF

Nexans ref. NCY 4.0 RF

  • Packaging: Coil (100m)
  • Approximate weight: 47 kg/m
  • Diameter over insulation: 4.2 mm
  • Nominal conductor diameter: 2.6 mm
  • Nominal insulation thickness: 0.8 mm
  • Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
  • Perm current rating in air 30°C: 27 A
  • Minimum Bend Radius - Installed: 25 mm

 

NCY 50.0 RF

Nexans ref. NCY 50.0 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 530 kg/m
  • Diameter over insulation: 11.9 mm
  • Nominal conductor diameter: 9.1 mm
  • Nominal insulation thickness: 1.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.386 Ohm/km
  • Perm current rating in air 30°C: 210 A
  • Minimum Bend Radius - Installed: 71 mm

 

NCY 6.0 RF

Nexans ref. NCY 6.0 RF

  • Packaging: Coil (100m)
  • Approximate weight: 70 kg/m
  • Diameter over insulation: 4.7 mm
  • Nominal conductor diameter: 3.1 mm
  • Nominal insulation thickness: 0.8 mm
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Perm current rating in air 30°C: 35 A
  • Minimum Bend Radius - Installed: 28 mm

 

NCY 70.0 RF

Nexans ref. NCY 70.0 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 730 kg/m
  • Diameter over insulation: 14.2 mm
  • Nominal conductor diameter: 11.4 mm
  • Nominal insulation thickness: 1.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.272 Ohm/km
  • Perm current rating in air 30°C: 260 A
  • Minimum Bend Radius - Installed: 85 mm

 

NCY 95.0 RF

Nexans ref. NCY 95.0 RF

  • Packaging: Cut to length (m)
  • Approximate weight: 965 kg/m
  • Diameter over insulation: 16.2 mm
  • Nominal conductor diameter: 13 mm
  • Nominal insulation thickness: 1.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Perm current rating in air 30°C: 310 A
  • Minimum Bend Radius - Installed: 97 mm

 

Description

Description

Standards

  • Product
    IEC 60227-5; IEC 60228
  • Test
    IEC 60332-1-2

Overview

Nexans provides a family of reliable products which respect the latest norms and the highest levels of security.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible class 5
Conductor material
Plain annealed copper
Conductor shape
Round, shiny, flexible
Insulation
PVC

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Usage characteristics

Usage characteristics

Field of application
LV
Flame retardant
IEC 60332-1-2
Installation type
Indoor
Maximum operating temperature (cables)
70 °C
Metric marking
METRIC MARKING

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close